How do you unlock the configuration menu on a Hayward pump

Unlock Configuration Menu To unlock the Configuration Menu, repeatedly press the Menu button until “Configuration Menu” is shown in the Menu Display. Press and hold the Menu Display for 5 seconds. Refer to your pool control’s manual to determine what options are offered within the Configuration Menu.

How do I unlock my Hayward configuration menu?

Press the ‘Menu’ until, ‘Configuration Menu-Locked’ appears. To unlock, press and hold the (<) & (>) until the text, on the display, changes from ‘Locked’ to ‘Unlocked‘ (unit will beep).

How do I reset my Hayward Aqua Plus?

With the pump running, take the power switch down to the “Off” position, and then back up to “Auto”. You should hear a click within 10 or 15 seconds. When you do, press the diagnostic button five times in a row. The system will go through a recalibration process.

How do you reset the logic on a Hayward Pro?

You must reset the system by entering the ‘Diagnostic Menu’ and then hitting the right arrow key once and then pushing the plus key once. This should reset the light and message.

How do I unlock my Hayward variable speed pump?

  1. POWER ON – Turn on the power to the pump.
  2. SET CURRENT DAY AND TIME – Press the Menu button. …
  3. UNLOCK CONFIGURATION MENU – Press and hold down the < and > buttons until the screen changes to “Configuration Menu Press > to Enter”.

What is Hayward Goldline?

Hayward® Industries, Inc., acquired Goldline Controls® in August 2004. The joining of Goldline and Hayward provides pool owners the first single source of the total pool management system, including pumps, filters, heaters, cleaners, lighting, salt chlorination and pool and spa automation.

How do I reset my Hayward EcoStar pump?

To manually clear, shut off the breaker supplying the EcoStar with power for at least 1 minute, then restore power.

How do I reset my Hayward Turbo Cell?

If the Inspect Cell Light is the only LED light flashing, then you can reset it by simply holding down the diagnostic button for 3 seconds, then release. The Inspect Cell indicator will now reset and will later come back on after another 500 hours of use.

What does chlorinator off no cell power mean?

‘No Cell Power’ means the current chlorinator cycle has been interrupted due to no voltage being detected when the cell power relay was turned on. Page 4. Turn off power to the controller.

How do you reset Aqua Rite control panel?

To reset, move the switch to ‘Off’ and then back to ‘Auto’. Wait for the relay to click (5 to 10 seconds). When the instant salt level is stable (and the negative sign still present), slide switch to ‘Super Chlorinate’ and back to ‘Auto’. It takes about 30 seconds for the unit to settle back on the default reading.

Article first time published on

How do you reset Aqua Rite chlorine generator?

To reset, turn the unit to Off and then back to Auto. Wait for the relay to click (5 to 10 seconds).

How do you troubleshoot a Hayward pool pump?

  1. Step 1: Check the Hoses. Tighten all hose connections on the pump and filter. …
  2. Step 2: Inspect the Pressure Gauge. …
  3. Step 3: Check the Skimmer Basket. …
  4. Step 4: Remove Debris. …
  5. Step 5: Inspect the Impeller. …
  6. Step 6: Backwash the Filter. …
  7. Step 7: Replace the Sand or DE.

What is quick clean on Hayward pump?

The pump is equipped with a Quick Clean feature, which can be engaged to temporarily run at higher or lower speeds ranging from 300 to 3450 RPM. At the end of a Quick Clean cycle, the pump will automatically return to the appropriate point in its programmed schedule.

Why won't my pool pump come on?

When your pool pump won’t turn on, the first place to look is for all issues electric: your breaker, your wiring, and the capacitor. … And by the way, if your pump is automatic, go ahead and check its timer to make sure it’s on in the first place. Just while you’re at it.

What is a pool pump drive?

The Motor. The electric motor is the driving force behind the wet end of the pump, literally and figuratively. The pump’s shaft spins up to 3,450 revolutions per minute to turn the impeller to draw water from your pool and then push it through your filter and back to the pool.

Why is my chlorinator off?

Air that has entered the system elsewhere, usually through a leaky O-ring in the pump, may be trapped in the chlorinator canister and cause an air lock. This will become evident by unscrewing the canister lid with the pool pump turned off. … After the canister fills with water, the lid should be reinstalled.

How do I know if my salt cell is bad?

Check salt” light on power center indicates problem but a routine water sample inspection shows salt levels are fine. Power center’s “Cell warning” light comes on and turns off after a cleaning but back on soon afterward. Voltage (higher than normal) and amperage (usually zero) level will show irregular readings.

How do you turn the aqualogic chlorinator on?

Turn power on at the main panel and turn the Aqua Logic control power circuit breaker on. The keypad will show the default display. The default display alternates between the day/time, air and pool (or spa) temperature, pool/spa sanitizer setting, and salt level.

What should my Hayward chlorinator be set at?

How much salt does the system require? Salt Systems work best with approximately 3200 parts per million (ppm) of salt, which is roughly the equivalent to a teaspoon of salt per gallon. However, all Hayward Salt Systems are designed to operate with salt levels anywhere from 2700 ppm to 3400 ppm.

What should my chlorinator be set at?

We suggest you start your salt chlorine generator at 50 percent output and run it for a couple of days, then check the chlorine level. In a balanced pool, a good chlorine level is 1-3 parts per million. If your chlorine levels are low, you can raise the percentage, and if it’s high you can lower the percentage.

How do I reset my Hayward Aqua Trol salt generator?

To reset, turn the unit to Off and then back to Auto. Wait for the relay to click (5 to 10 seconds). Desired Output % Dial 1 to 100% sets the level of cell operation in % of operating time.. Example: 50% (factory default) cell is operating and generating chlorine 50% of the total pump/filter operating time.