What is the maximum length of flexible duct

Flexible air connectors which are listed to UL 181 are allowed by the standard in lengths up to 14 feet. This product is specifically evaluated for the maximum length up to 14 feet, and the manufacturer’s installation instructions are reviewed to ensure proper installation up to this length.

How long can you run flex duct?

1 Length Limitation. Factory-made flexible air ducts and connectors shall be not more than 5 feet (1524 mm) in length and shall not be used in lieu of rigid elbows or fittings. That’s a pretty strong limitation.

What is the largest size of flex duct?

For residential HVAC systems, insulated flex duct typically comes in diameters of 4 inches through 10 inches; above 10 inches, it comes in even sizes of 12, 14, 16, etc., up to 22 inches measured at the radius of the metal helix.

What is the maximum length of duct?

The maximum length for flexible ducting should be no longer than 1.5 metres for axial fans, 6 metres for centrifugal fans (up to 30 l/sec) and 3 metres (from 31 l/sec to 60 l/sec). Depending on the flow rate, the maximum number of bends the flexible ducting system can have is 2.

What lengths does ductwork come in?

The size of ductwork affects the amount of airflow and its velocity and is very important in how well the HVAC system operates. Rectangular ducting can come in various sizes from 3” x 7” up to 35” x 40”; and round ducting can be anywhere from 4” to 41” in diameter.

What is the maximum length of trunk duct in an extended plenum system?

Extended plenum system Branch runs to feed the supply outlets are tapped into the extended plenum(s). The best results are achieved when the maximum length of the extended plenum is not greater than 24 ft from the air handler or furnace.

How often should flex duct be supported?

Supports should be installed at least every once 4 feet. The maximum allowable sag in flexible duct is one-half inch per foot.

How many CFM will 12 flex carry?

Duct Size (Inches)Flex Duct Airflow (CFM)10 inches300 CFM12 inches480 CFM14 inches700 CFM16 inches1,000 CFM

How is flexible duct measured?

One simply needs a ruler or measuring tape along with the end of the hose or outlet. Keep in mind that you have to begin the measurements from the interior wall of the circle. The distance to the opposing point of the circle is the measure of the flex duct sizing for the inner diameter.

How do you calculate duct size?

To calculate the required equipment size, divide the HVAC load for the entire building by 12,000. One ton equals 12,000 BTUs, so if a house or office needs 24,000 BTUs, it will take a 2-ton HVAC unit.

Article first time published on

What is duct diameter?

The equivalent diameter is the diameter of a circular duct or pipe that gives the same pressure loss as an equivalent rectangular duct or pipe. … The rectangular dimensions and the air flow volume are adapted to the equal friction loss method of sizing ventilation duct systems.

What size ductwork do I need for a 5 ton unit?

Using this approach, two 20-in. x 25-in. return grilles will be the right choice for a five-ton HVAC system in order to actually deliver 2,000 cfm back to the blower without causing the return to hemorrhage.

What size return duct do I need for a 3 ton?

Electric heat pumps shall be tested in accordance with UL 559 or UL 1995. Example: 3.5 ton heat pump. The duct for this system must be sized by using 6 square inches of clear duct area for each 1000 BTU of cooling. Each ton of cooling contains 12,000 BTU.

What are standard round duct sizes?

Recommendations for round duct diameters for laboratories are: 25-mm (1″) increments from 150 to 250 mm (6″ to 10″) diameter. 50-mm (2″) increments from 250 to 1,000 mm (10″ to 40″) diameter. 100-mm (4″) increments above 1,000 mm (40″) diameter.

Can flex duct be used for return air?

Yes! You can use flex ducts for your return ducts. However, you have to make sure it fulfills all the necessary criteria. These include pressure checks, proper wrapping, and marking, airflow control, etc.

How many types of HVAC ducts are there?

There are three main types of rigid ductwork: sheet metal ducts, fiberglass lined ducts, and fiberboard ducts. Sheet Metal Ducts: Sheet metal ducts are usually made of either galvanized steel or aluminum.

What is ducting in HVAC?

Ducts are conduits or passages used in heating, ventilation, and air conditioning (HVAC) to deliver and remove air. The needed airflows include, for example, supply air, return air, and exhaust air. Ducts commonly also deliver ventilation air as part of the supply air. … A duct system is also called ductwork.

How many CFM does a 4 inch duct have?

Reviewing the chart, a 4” pipe will convey 395 CFM at 4500 FPM. This means that a 4” pick-up on a machine will use 395 CFM from the filtering system; or, if you know that a machine will require approximately 400 CFM to remove the waste, you should use a 4” pipe for that purpose.

How many CFM is a 5 ton unit?

A 5-ton system should have have 2,000 cfm, a 6-ton system should have 2,400 cfm, and so on and son. Measuring how much airflow measurements deviate from that math is a quick way to diagnose airflow issues in a residential duct system.

How do you calculate CFM for duct size?

CFM calculation requires the size of your HVAC unit in tons to be multiplied by 400 (the average output of an HVAC unit). The total must then be divided by the square footage of your house. The air flow from your system also depends on the rate of friction loss of ducts.

What is the CFM formula?

CFM = (fpm * area), where fpm is the feet per minute. To find the cubic feet per minute, substitute the FPM value with the area after the area is squared.

How big does a return air duct need to be?

The Size Of Your Return Ducts If you are installing just one or two return vents, you will want to go with a 12-inch return for 2-ton units and lower. 14- inches for 3 and up. 16-inch should be suitable for 4 ton systems, whereas 5 might require 18-inch returns.

What is the good rule of thumb in sizing Ductworks?

Determining the Right Duct Size When you hire a professional to install your ductwork, they’ll often size your HVAC ducts using a rule of thumb that states an air conditioner with one-ton capacity should be installed for every 500 square feet of air-conditioned floor area.

How big should return air vents be?

A typical supply vent is 4 by 10 to 12 inches and a typical return vent is 16 by 20 inches or larger. Houses often have two or more return collecting points, each with a filter, which join before re-entering the heating unit.

What happens if there is not enough return air?

If there is not enough return air available, your HVAC system will not heat or cool properly. … If not enough air is brought back, your HVAC system will not be able to keep up with temperature demands. In some cases, two returns may be necessary to provide enough return air.

Can a return vent be on the floor?

An air return vent is part of the HVAC system. Return vents are usually larger than heat registers and can generally be found close to the ground or in the floor in older homes or on a wall close to a ceiling in newer homes.

How many vents should a 2.5 ton AC unit have?

For instance a 2.5 ton system (Approximately 400 CFM per ton) would require (2) 14” flexible return ducts or (1) very short flexible 18” duct to move the 1000 CFM required by the 2.5 ton system.